ORIGINAL ARTICLE |
|
Year : 2020 | Volume
: 15
| Issue : 4 | Page : 312-322 |
|
LC-MS based stability-indicating method for studying the degradation of lonidamine under physical and chemical stress conditions
Ankit Kanaiyalal Rochani1, Margaret Wheatley2, Brian Edward Oeffinger2, John Robert Eisenbrey3, Gagan Kaushal1
1 Department of Pharmaceutical Sciences, Jefferson College of Pharmacy, Thomas Jefferson University, Philadelphia, USA 2 School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, USA 3 Department of Radiology, Thomas Jefferson University, Philadelphia, USA
Correspondence Address:
Gagan Kaushal Department of Pharmaceutical Sciences, Jefferson College of Pharmacy, Thomas Jefferson University, Philadelphia USA
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/1735-5362.293509
|
|
Background and purpose: Lonidamine is a hexokinase II inhibitor, works as an anticancer molecule, and is extensively explored in clinical trials. Limited information prevails about the stability-indicating methods which could determine the forced degradation of lonidamine under stressed conditions. Hence, we report the use of a rapid, sensitive, reproducible, and highly accurate liquid chromatography and mass spectrometry method to analyze lonidamine degradation.
Experimental approach: The Xbridge BEH shield reverse phase C18 column (2.5 μm, 4.6 × 75 mm) using isocratic 50:50 water: acetonitrile with 0.1% formic acid can detect lonidamine with help of mass spectrometer in tandem with an ultraviolet (UV) detector at 260 nm wavelength.
Findings/ Results: A linear curve with r2 > 0.99 was obtained for tandem liquid chromatography-mass spectrometry (LC-MS)-UV based detections. This study demonstrated (in the present set up of isocratic elution) that LC-MS based detection has a relatively high sensitivity (S/N (10 ng/mL): 220 and S/N (20 ng/mL): 945) and accuracy at lower detection and quantitation levels, respectively. In addition to developing the LC-MS method, we also report that the current method is stability-indicating and shows that lonidamine gets degraded over time under all three stress conditions; acidic, basic, and oxidative.
Conclusion and implications: LC-MS based quantitation of lonidamine proved to be a better method compared to high-performance liquid chromatography (HPLC)-UV detections for mapping lonidamine degradation. This is the first report on the stability-indicating method for studying the forced degradation of lonidamine using LC-MS method.
|
|
|
|
[FULL TEXT] [PDF]* |
|
 |
|